Demi menjaga akurasi dan ketepatan pengukuran berat atau massa suatu benda sangat dibutuhkan berbagai Aksesoris yang mampu mengalisa berat benda tersebut dengan ketepatan yang jelas dan tepat.
Ada beberapa Aksesoris timbangan ,yaitu :
1. Cable Load Cell
FEATURES :
Cable load cell use for connection from junction box to indicator there are 2 model of the cable:
• 6 wire + 1 shield ( model CB-662 )
• 4 wire + 1 shield ( Model CB-462 )
2. Cable SB
FEATURES :
This cable for connection between indicator and score board standard lenght : 10 meters ( can customised of lenght).
There are 4 model plug for excellent’s product of indicator to SB-YHL series:
• For indicator A1+p /A9+p (Cable SB YHL - A1+p/A9+p)
• For indicator A12E /A12ESS (Cable SB YHL - A12E/A12ESS)
• For indicator E8A (Cable SB YHL - E8A)
• For indicator C602 (Cable SB YHL - C602)
There are 5 model plug for excellent’s product of indicator to SB-RS series:
• For indicator A1+p /A9+p (Cable SB RS - A1+p/A9+p)
• For indicator E8A (Cable SB RS - E8A)
• For indicator GBSS / 315 - A1 (Cable SB RS - GBSS/315A1)
• For indicator GW (Cable SB RS - GW)
• For indicator C602 (Cable SB RS - C602)
3. Cable RS
FEATURES :
This cable for connection between indicator and personal computer standard lenght : 2.5meters ( can customised of lenght) there are 6 model plug for excellent’s product of indicator:
• For indicator A1+p /A9+p (Cable RS - A1+p/A9+p)
• For indicator E8A (Cable RS - E8A)
• For indicator A12E /A12ESS / A15E (Cable RS - A12E/A12ESS/A15E)
• For indicator GBSS / 315 - A1 (Cable RS GBSS/315A1)
• For indicator GW (Cable RS - GW)
• For indicator C602 (Cable RS - C602)
4. Ticket Printer
SPECIFICATION :
Communication interface serial (RS-232 C)
Selectable of baud rate, Data bit, Parity and stop bits.
Can connect with Excellent’s product of Indicator GW-RS, XK-315-GBSS and XK315-A1
Print out format depend the software of indicator, see the catalog of indicator for the format
Selectable of baud rate, Data bit, Parity and stop bits.
Can connect with Excellent’s product of Indicator GW-RS, XK-315-GBSS and XK315-A1
Print out format depend the software of indicator, see the catalog of indicator for the format
5. Score Board
INTRODUCTION :
Score board for weighing device by viewing weighing result from long distance
Weighing indicator should be equipped with corresponding communication interface for connect with score board
Model SB - YHL series use current loop communication interface
SPECIFICATION :
• Dynamic scan flip - latching technology
• High-lighted digital segment and broad eyesight
• Gross or net weight display from indicator or other output system
• Power: AC 187 - 242 V; 49 - 51Hz
• Communication interface: current loop way
Model Dimension (mm) Digits
A B C D
SB - YHL - 1" 257 100 14.5 25.4 6
SB - YHL - 3" 490 180 47.5 76.2 6
SB - YHL - 5" 780 260 75 127 6
SB - YHL - 8" 990 510 120 203.2 6
6. Transmitter Wireless
This device for used in weighing scale , from load cell (platform, floor , truck scale) to Indicator without cable connection. Applied to weighing scale which need long distance for display indicator or difficulty install the cable connection so need used the transmitter wireless.
SPECIFICATIONS :
Accuracy 1/10,000 for any indicator Load cell 1 to 12 load cells 350Ω
Frequency bands 433MH z
Power consumption 270 hours under weighing mode for one load cell 350Ω, 29 months under sleeping mode(battery should be recharged every 5months)
Range 100 meters
Working temperature-10 ˚C to +60 ˚C
Transmitter: Excitation 3.3v, Input <12.9 mv, Power 4 - 6VDC
Receiver: Excitation 5-15V, Output 3mV/V
Load cell and Indicator wiring connection
1 +Excitation
2 +Signal
3 -Signal
4 -Excitation
5 Shield
Enclosure: Aluminum 110 x 76 x 30mm
Turn on/off: Remote On/Off through weighing indicator.
Power supply: AC/DC Rechargeable battery.
7. Hydro Kit
This balance is comprised electronic balance and instrument of hydrostatics.
By Archimedes Theorem, they can measure solid density, size and weight
Use capacity of balance more than 2000g for equip the instrument of Hydrostatic weighing
Hydrostatical instrument:
Shape size: 300 x 330 x 335mm
Container size: Φ185 x 220mm
Faucet to container’s bottom : 185mm
Nacelle size: Φ150 x 150mm
8. Simulator Load cell
INTRODUCTION :
XY1 load cell simulator adopts high precision D/A converter, able to simulate various output signals from strain gauge load cell of weighing, pressing, ergo metering, accumulation and so on.
Output range of the simulator is from 0 – 2.0000mV/V and non-linearity is <0.005%FS.
Its widely applied to verify and check weighing indicator and so on alike measuring instrument connected to strain gauge load cell.
FUNCTION :
• Able to set display segment of decrease or increase (F0 model)
• Able to output signal accordance with value set by key (F1 model)
• Able to output signal grade by grade in accordance with set range (F2 model)
• Able to detect environment temperature
• Able to measure excitation of the indicator measured
• Able to program by key
• Able to program by PC then download the program by serial port
• Able to execute user define program, output signal in accordance with program, simulate the working procedure of auto weighing instrument
• Work with excitation power from indicator
PARAMETER :
• Non-linearity : ≤0.005%F.S
• Output precision at F.S : ≤0.01%F.S(25 ˚C)
• Output temperature rate at F.S : ≤5ppm/˚C
• Excitation power range : DC 5 - 10V , 10 - 20V
• Output Range : 0 - 2 mv/v
• Outer resolution : 0.0001mV/V
• Inner resolution : 1.000.000 code
• Working temperature range : 0 - 40 ˚C
• Stability : ≤50ppm/month
• Input excitation current: excitation (V)/700 (ohm) + 5 mA
• Output resistance: about 300 ohm
• Size : 145 x 85 x 30 mm
• Weight : 158g
9. Junction Box
INTRODUCTION :
Able to connect with strain gauge load cell at resistance 350 - 800 ohm; excitation 3-15 vdc
FUNCTION :
Connection mode model : parallel and serial mode
For quantiy of load cell : 4 (JB-SS-4CH), 6 (JB-SS-6CH), 8 (JB-SS-8CH)
High precision potentiometer
Wire connection method with selection of compacting or welding
For parallel mode equipped with TVS pipe for anti-surge protection
Adjust range :
* Load cell 350 ohm : serial mode about 5%, parallel mode about 3%
* Load cell 700 ohm : serial mode about 3%, parallel mode about 2%
10. Round Cutter
SPECIFICATIONS :
Cutting size : Ø 113mm
Application For: Cutting Material such as textile, paper and etc. For get a standard of weigh value used balance scale for weigh the material’s cutted
Itulah beberapa jenis Aksesoris yang dapat anda lihat,untuk melihat spesifikasi Aksesoris atau Product lainnya Anda dapat mengunjungi www.timbanganindonesia.com yang merupakan distributor timbangan terbesar di Jakarta.
0 komentar: